Assessment of the 2016 National Institute for Health and Care Excellence high-sensitivity troponin rule-out strategy.

Carlton, E.W., Pickering, J.W., Greenslade, J., Cullen, L., Than, M., Kendall, J., Body, R., Parsonage, W.A., Khattab, A. D. and Greaves, K., 2018. Assessment of the 2016 National Institute for Health and Care Excellence high-sensitivity troponin rule-out strategy. Heart, 104 (8), 665-672.

Full text available as:

[img]
Preview
PDF (OPEN ACCESS ARTICLE)
665.full.pdf - Published Version
Available under License Creative Commons Attribution Non-commercial.

1MB

DOI: 10.1136/heartjnl-2017-311983

Abstract

OBJECTIVE: We aimed to evaluate the limit of detection of high-sensitivity troponin (hs-cTn) and Thrombolysis In Myocardial Infarction (TIMI) score combination rule-out strategy suggested within the 2016 National Institute for Health and Care Excellence (NICE) Chest Pain of Recent Onset guidelines and establish the optimal TIMI score threshold for clinical use. METHODS: A pooled analysis of adult patients presenting to the emergency department with chest pain and a non-ischaemic ECG, recruited into six prospective studies, from Australia, New Zealand and the UK. We evaluated the sensitivity of TIMI score thresholds from 0 to 2 alongside hs-cTnT or hs-cTnI for the primary outcome of major adverse cardiac events within 30 days. RESULTS: Data were available for 3159 patients for hs-cTnT and 4532 for hs-cTnI, of these 376 (11.9%) and 445 (9.8%) had major adverse cardiac events, respectively. Using a TIMI score of 0, the sensitivity for the primary outcome was 99.5% (95% CI 98.1% to 99.9%) alongside hs-cTnT and 98.9% (97.4% to 99.6%)%) alongside hs-cTnI, identifying 17.9% and 21.0% of patients as low risk, respectively. For a TIMI score ≤1 sensitivity was 98.9% (97.3% to 99.7%)%) alongside hs-cTnT and 98.4% (96.8% to 99.4%)%) alongside hs-cTnI, identifying 28.1% and 35.7% as low risk, respectively. For TIMI≤2, meta-sensitivity was <98% with either assay. CONCLUSIONS: Our findings support the rule-out strategy suggested by NICE. The TIMI score threshold suggested for clinical use is 0. The proportion of patients identified as low risk (18%-21%) and suitable for early discharge using this threshold may be sufficient to encourage change of practice. TRIAL REGISTRATION NUMBERS: ADAPT observational study/IMPACT intervention trial ACTRN12611001069943.ADAPT-ADP randomised controlled trial ACTRN12610000766011.EDACS-ADP randomised controlled trial ACTRN12613000745741.TRUST observational study ISRCTN no. 21109279.

Item Type:Article
ISSN:1355-6037
Uncontrolled Keywords:acute coronary syndrome
Group:Faculty of Health & Social Sciences
ID Code:29859
Deposited By: Symplectic RT2
Deposited On:10 Oct 2017 15:03
Last Modified:14 Mar 2022 14:07

Downloads

Downloads per month over past year

More statistics for this item...
Repository Staff Only -