Bahadori, S., Davenport, P., Immins, T. and Wainwright, T., 2019. Validation of joint angle measurements: comparison of a novel low cost marker-less system with an industry standard marker-based system. Journal of Medical Engineering & Technology, 43 (1), 19-24.
Full text available as:
|
PDF
Manuscript (4).pdf - Accepted Version Available under License Creative Commons Attribution Non-commercial No Derivatives. 83kB | |
Copyright to original material in this document is with the original owner(s). Access to this content through BURO is granted on condition that you use it only for research, scholarly or other non-commercial purposes. If you wish to use it for any other purposes, you must contact BU via BURO@bournemouth.ac.uk. Any third party copyright material in this document remains the property of its respective owner(s). BU grants no licence for further use of that third party material. |
DOI: 10.1080/03091902.2019.1599072
Abstract
Human motion tracking is widely used for assessment of movement dysfunction in orthopaedic patients. Currently, most clinical motion analysis centres use marker based three-dimensional (3D) systems as they are deemed to be the most accurate method. However, due to space, costs and logistics they are not available in many clinical settings. This study compared joint angles measured in functional tests using the novel low-cost Microsoft Kinect Perfect Phorm system with the established marker based Nexus VICON system. When measuring right and left knee flexion, the average difference between the VICON and Kinect Perfect Phorm measurement was 13.2%, with a SD of 19.6. Both overestimation and underestimation of the joint angle was recorded in different participants. Although the average percentage difference during hip abduction tests was lower at -3.9%, the range of error was far greater (SD=75). From this, it can be concluded that the level of accuracy presented in the new low cost Kinect Perfect Phorm system is not yet suitable for clinical assessments. However, for general tests of performance, and for tracking cases where absolute accuracy is less critical, future versions of this software may have a place.
Item Type: | Article |
---|---|
ISSN: | 0309-1902 |
Uncontrolled Keywords: | Kinect, Nexus VICON, motion capture, movement analysis, system performance |
Group: | Faculty of Health & Social Sciences |
ID Code: | 32147 |
Deposited By: | Symplectic RT2 |
Deposited On: | 24 Apr 2019 14:28 |
Last Modified: | 14 Mar 2022 14:15 |
Downloads
Downloads per month over past year
Repository Staff Only - |