Skip to main content

Concurrent validity of skin-based motion capture systems in measuring dynamic lumbar intervertebral angles.

Frey, M., Breen, A., Rix, J. and De Carvalho, D., 2025. Concurrent validity of skin-based motion capture systems in measuring dynamic lumbar intervertebral angles. Journal of Biomechanics, 180, 112503.

Full text available as:

[thumbnail of R1_MANUSCRIPT November 24_clean.pdf] PDF
R1_MANUSCRIPT November 24_clean.pdf - Accepted Version
Restricted to Repository staff only until 5 January 2026.
Available under License Creative Commons Attribution Non-commercial No Derivatives.

196kB

DOI: 10.1016/j.jbiomech.2025.112503

Abstract

Spine kinematics are commonly measured by external sensors such as motion capture and accelerometers. However, these skin-based measures cannot directly capture intervertebral motion of the lumbar spine. To date, research in this area has focused on the estimation of intervertebral kinematics using static trials but no study has analyzed agreement throughout the dynamic range of motion. This study investigated the agreement between skin-based sensors (accelerometers and motion capture) and quantitative fluoroscopy (QF) in measuring lumbar spine kinematics for the duration of complete flexion and extension motion in a healthy female population. Twenty female participants (age 30–57, BMI < 30) were guided through a standing flexion and extension bending protocol while spine kinematics were concurrently measured by QF (L2, L3, L4, L5, and S1) and motion capture sensors and accelerometers positioned over the spinous processes of L2, L4, and S1. Intervertebral angles (L2-L4, L4-S1, L2-S1) and individual vertebrae levels were compared between measures. Non-parametric limits of agreement between QF and skin-based markers were greatest at the end-range of motion for both flexion and extension, but differences increased variably between participants, sometimes over-and sometimes underestimating angles, thus, disproving the common assumption that it increases linearly. The two skin-based marker systems showed good agreement with one another showing that they can be used interchangeably but they can only be used to estimate lumbar spine kinematics. Normalizing angles to a change in angle and considering the posture of instrumentation would be beneficial to reduce potential sources of errors.

Item Type:Article
ISSN:0021-9290
Uncontrolled Keywords:Accelerometers; Low back; Motion capture; Skin based marker error; Spine kinematics; Humans; Female; Lumbar Vertebrae; Adult; Range of Motion, Articular; Biomechanical Phenomena; Middle Aged; Accelerometry; Fluoroscopy; Movement; Skin; Skin Physiological Phenomena; Motion Capture
Group:Faculty of Science & Technology
ID Code:40830
Deposited By: Symplectic RT2
Deposited On:05 Mar 2025 12:49
Last Modified:05 Mar 2025 12:49

Downloads

Downloads per month over past year

More statistics for this item...
Repository Staff Only -