Gavin, J., Willems, M.E.T. and Myers, S.D., 2014. Reproducibility of lactate markers during 4 and 8 min stage incremental running: a pilot study. Journal of Science and Medicine in Sport, 17 (6), 635 - 639.
Full text available as:
|
PDF (Article)
JSAMS%20Manuscript.docx-2.pdf - Accepted Version 120kB | |
|
PDF (Diagrams)
Table_1.docx-1.pdf - Accepted Version 47kB | |
|
PDF (Figures)
Figure_1A.docx.pdf - Accepted Version 36kB | |
Copyright to original material in this document is with the original owner(s). Access to this content through BURO is granted on condition that you use it only for research, scholarly or other non-commercial purposes. If you wish to use it for any other purposes, you must contact BU via BURO@bournemouth.ac.uk. Any third party copyright material in this document remains the property of its respective owner(s). BU grants no licence for further use of that third party material. |
DOI: 10.1016/j.jsams.2013.08.006
Abstract
OBJECTIVES: This study examined the reproducibility of speed corresponding to specific lactate markers during incremental treadmill running of normal and prolonged stage durations. DESIGN: Nineteen healthy participants (14 male, 5 female) performed repeated, incremental treadmill running trials of 4 and 8 min stages on separate days to examine the test-retest reproducibility of speed at lactate markers. Two trials were completed for each duration in a randomised order. METHODS: Fingertip blood samples drawn upon stage completion were analysed for plasma lactate, then used to determine running speed at: 2.0, 3.5, and 4.0 mmol l(-1) fixed blood lactate accumulations (FBLA), a 1 mmol l(-1) rise from baseline, and the markers: the deviation maximum (Dmax), the Dmax of the second curve derivative (D2L(max)), the lactate threshold (LT) and log-log LT. RESULTS: The 2.0 mmol l(-1) FBLA reported the lowest mean bias between 4 min trials (-0.06 km h(-1)), with the narrowest limits of agreement (LoA) (-1.78 to 1.66 km h(-1)). The Dmax had the second lowest bias (0.14 km h(-1)), D2L(max) the second narrowest LoA (-1.93 to 2.90 km h(-1)). For 8 min stages, the 1 mmol l(-1) rise demonstrated, low mean bias (-0.13 km h(-1)) and narrowest LoA (-1.22 to 0.97 km h(-1)) between trials. CONCLUSIONS: This preliminary report suggests the reproducibility of running speed at lactate summary markers is influenced by stage duration for incremental treadmill running. Varied marker reproducibility between 4 and 8 min stages indicates different blood lactate response, and therefore workload calculation, according to stage length. Consideration of marker construct is recommended.
Item Type: | Article |
---|---|
ISSN: | 1440-2440 |
Uncontrolled Keywords: | Sports medicine ; Running ; Lactate testing ; Incremental exercise ; Exercise tolerance ; Training prescription |
Group: | Bournemouth University Business School |