Skip to main content

Moving back: The radiation dose received from lumbar spine quantitative fluoroscopy compared to lumbar spine radiographs with suggestions for dose reduction.

Mellor, F. E., Thomas, P. and Breen, A. C., 2014. Moving back: The radiation dose received from lumbar spine quantitative fluoroscopy compared to lumbar spine radiographs with suggestions for dose reduction. Radiography, 20 (3), 251 - 257 .

Full text available as:

[img]
Preview
PDF
Mellor Radiography.pdf - Published Version
Available under License Creative Commons Attribution Non-commercial Share Alike.

1MB

DOI: 10.1016/j.radi.2014.03.010

Abstract

Purpose: Quantitative fluoroscopy is an emerging technology for assessing continuous inter-vertebral motion in the lumbar spine, but information on radiation dose is not yet available. The purposes of this study were to compare the radiation dose from quantitative fluoroscopy of the lumbar spine with lumbar spine radiographs, and identify opportunities for dose reduction in quantitative fluoroscopy. Methods: Internationally reported dose area product (DAP) and effective dose data for lumbar spine radiographs were compared with the same for quantitative fluoroscopy and with data from a local hospital for functional radiographs (weight bearing AP, lateral, and/or flexion and extension) (n = 27). The effects of procedure time, age, weight, height and body mass index on the fluoroscopy dose were determined by multiple linear regression using SPSS v19 software (IBM Corp., Armonck, NY, USA). Results and conclusion: The effective dose (and therefore the estimated risk) for quantitative fluoroscopy is 0.561 mSv which is lower than in most published data for lumbar spine radiography.The dose area product (DAP) for sagittal (flexion + extension) quantitative fluoroscopy is 3.94 Gy cm2 which is lower than local data for two view (flexion and extension) functional radiographs (4.25 Gy cm2), and combined coronal and sagittal dose from quantitative fluoroscopy (6.13 Gy cm2) is lower than for four view functional radiography (7.34 Gy cm2).Conversely DAP for coronal and sagittal quantitative fluoroscopy combined (6.13 Gy cm2) is higher than that published for both lumbar AP or lateral radiographs, with the exception of Nordic countries combined data.Weight, procedure time and age were independently positively associated with total dose, and height (after adjusting for weight) was negatively associated, thus as height increased, the DAP decreased. © 2014 The College of Radiographers.

Item Type:Article
ISSN:1078-8174
Uncontrolled Keywords:Continuous motion ; Flexion-extension ; Inter-vertebral ; Low back pain ; Movement disorders ; Spine kinematics
Group:Faculty of Health & Social Sciences
ID Code:22498
Deposited By: Symplectic RT2
Deposited On:25 Sep 2015 13:03
Last Modified:14 Mar 2022 13:53

Downloads

Downloads per month over past year

More statistics for this item...