Jones, M.T., Heiden, E., Fogg, C., Meredith, P., Smith, G. B., Sayer, N., Toft, L., Williams, E., Williams, M., Brown, T., Gates, J., Lodge, D., Bassett, P., Amos, M., Chauhan, M., Begum, S., Rason, M., Winter, J., Longstaff, J. and Chauhan, A.J., 2020. An Evaluation of Agreement of Breathing Rates Measured by a Novel Device, Manual Counting, and Other Techniques Used in Clinical Practice: Protocol for the Observational VENTILATE Study. JMIR Research Protocols, 9 (7), -.
Full text available as:
|
PDF (OPEN ACCESS ARTICLE)
pdf.pdf - Published Version Available under License Creative Commons Attribution. 686kB | |
Copyright to original material in this document is with the original owner(s). Access to this content through BURO is granted on condition that you use it only for research, scholarly or other non-commercial purposes. If you wish to use it for any other purposes, you must contact BU via BURO@bournemouth.ac.uk. Any third party copyright material in this document remains the property of its respective owner(s). BU grants no licence for further use of that third party material. |
DOI: 10.2196/15437
Abstract
BACKGROUND: Respiratory rate (RR) is the most sensitive physiological observation to predict clinical deterioration on hospital wards, and poor clinical monitoring has been highlighted as a primary contributor to avoidable mortality. Patients in intensive care have their RR monitored continuously, but this equipment is rarely available on general hospital wards. OBJECTIVE: The primary objective is to assess the accuracy of the RespiraSense device in comparison with other methods currently used in clinical practice. The secondary objective is to assess the accuracy of the RespiraSense device in participants in different positions and when reading aloud. METHODS: A single-center, prospective observational study will investigate the agreement of the RespiraSense device as compared with other device measurements (capnography, electrocardiogram) and the current standard measurement of RR (manual counting by a trained health care professional). The different methods will be employed concurrently on the same participant as part of a single study visit. RESULTS: Recruitment to this study has not yet started as funding decisions are still pending. Therefore, results are not available at this stage. It is anticipated that the data required could be collected within 2 months of first recruitment to the study and data analysis completed within 6 months of the study start date. CONCLUSIONS: The Evaluation of Agreement of Breathing Rates Measured by a Novel Device, Manual Counting, and Other Techniques Used in Clinical Practice (VENTILATE) study will provide further validation of the use of the RespiraSense device in subjects with abnormal respiratory rates. INTERNATIONAL REGISTERED REPORT IDENTIFIER (IRRID): PRR1-10.2196/15437.
Item Type: | Article |
---|---|
ISSN: | 1929-0748 |
Uncontrolled Keywords: | bradypnoea ; device ; medical ; monitoring ; piezoelectric ; respiration ; respiratory ; respiratory function tests ; tachypnoea ; telemetry ; vital signs |
Group: | Faculty of Health & Social Sciences |
ID Code: | 34532 |
Deposited By: | Symplectic RT2 |
Deposited On: | 09 Sep 2020 10:26 |
Last Modified: | 14 Mar 2022 14:24 |
Downloads
Downloads per month over past year
Repository Staff Only - |