Skip to main content

An Evaluation of Agreement of Breathing Rates Measured by a Novel Device, Manual Counting, and Other Techniques Used in Clinical Practice: Protocol for the Observational VENTILATE Study.

Jones, M.T., Heiden, E., Fogg, C., Meredith, P., Smith, G. B., Sayer, N., Toft, L., Williams, E., Williams, M., Brown, T., Gates, J., Lodge, D., Bassett, P., Amos, M., Chauhan, M., Begum, S., Rason, M., Winter, J., Longstaff, J. and Chauhan, A.J., 2020. An Evaluation of Agreement of Breathing Rates Measured by a Novel Device, Manual Counting, and Other Techniques Used in Clinical Practice: Protocol for the Observational VENTILATE Study. JMIR Research Protocols, 9 (7), -.

Full text available as:

[img]
Preview
PDF (OPEN ACCESS ARTICLE)
pdf.pdf - Published Version
Available under License Creative Commons Attribution.

686kB

DOI: 10.2196/15437

Abstract

BACKGROUND: Respiratory rate (RR) is the most sensitive physiological observation to predict clinical deterioration on hospital wards, and poor clinical monitoring has been highlighted as a primary contributor to avoidable mortality. Patients in intensive care have their RR monitored continuously, but this equipment is rarely available on general hospital wards. OBJECTIVE: The primary objective is to assess the accuracy of the RespiraSense device in comparison with other methods currently used in clinical practice. The secondary objective is to assess the accuracy of the RespiraSense device in participants in different positions and when reading aloud. METHODS: A single-center, prospective observational study will investigate the agreement of the RespiraSense device as compared with other device measurements (capnography, electrocardiogram) and the current standard measurement of RR (manual counting by a trained health care professional). The different methods will be employed concurrently on the same participant as part of a single study visit. RESULTS: Recruitment to this study has not yet started as funding decisions are still pending. Therefore, results are not available at this stage. It is anticipated that the data required could be collected within 2 months of first recruitment to the study and data analysis completed within 6 months of the study start date. CONCLUSIONS: The Evaluation of Agreement of Breathing Rates Measured by a Novel Device, Manual Counting, and Other Techniques Used in Clinical Practice (VENTILATE) study will provide further validation of the use of the RespiraSense device in subjects with abnormal respiratory rates. INTERNATIONAL REGISTERED REPORT IDENTIFIER (IRRID): PRR1-10.2196/15437.

Item Type:Article
ISSN:1929-0748
Uncontrolled Keywords:bradypnoea ; device ; medical ; monitoring ; piezoelectric ; respiration ; respiratory ; respiratory function tests ; tachypnoea ; telemetry ; vital signs
Group:Faculty of Health & Social Sciences
ID Code:34532
Deposited By: Symplectic RT2
Deposited On:09 Sep 2020 10:26
Last Modified:14 Mar 2022 14:24

Downloads

Downloads per month over past year

More statistics for this item...
Repository Staff Only -