Cheshire, J., Lissauer, D., Parry-Smith, W., Tobias, A., Smith, G. B., Isaacs, R., Hundley, V. and Modified Obstetric Early Warning Systems (MObs) Research Group, , 2021. Escalation triggers and expected responses in obstetric early warning systems used in UK consultant-led maternity units. Resuscitation Plus, 5 (March), 100060.
Full text available as:
|
PDF (OPEN ACCESS ARTICLE)
1-s2.0-S2666520420300618-main.pdf - Published Version Available under License Creative Commons Attribution Non-commercial No Derivatives. 4MB | |
Copyright to original material in this document is with the original owner(s). Access to this content through BURO is granted on condition that you use it only for research, scholarly or other non-commercial purposes. If you wish to use it for any other purposes, you must contact BU via BURO@bournemouth.ac.uk. Any third party copyright material in this document remains the property of its respective owner(s). BU grants no licence for further use of that third party material. |
DOI: 10.1016/j.resplu.2020.100060
Abstract
Background: The use of obstetric early warning systems (OEWS) are recommended as an adjunct to reduce maternal morbidity and mortality. The aim of this review was to document the variation in OEWS trigger thresholds and the quality of information included within accompanying escalation protocols. Methods: A review of OEWS charts and escalation policies across consultant-led maternity units in the UK (n = 147) was conducted. OEWS charts were analysed for variation in the values of physiological parameters triggering different levels of clinical escalation. Relevant data within the escalation protocols were also searched for: urgency of clinical response; seniority of responder; frequency of on-going clinical monitoring; and clinical setting recommended for on-going care. Results: The values of physiological parameters triggering specific clinical responses varied significantly between OEWS. Only 99 OEWS charts (67.3%) had an escalation protocol as part of the chart. For 29 charts (19.7%), the only escalation information included was generic, for example to "contact a doctor if triggers". Only 76 (51.7%) charts detailed the required seniority of responder, 37 (25.2%) the frequency for on-going clinical monitoring, eight (5.4%) the urgency of clinical response and two (1.4%) the recommended clinical setting for on-going care. Conclusion: The observed variations in the trigger thresholds used in OEWS charts and the quality of information included within the accompanying escalation protocols is likely to lead to suboptimal detection and response to clinical deterioration during pregnancy and the post-partum period. The development of a national OEWS and escalation protocol would help to standardise care across obstetric units.
Item Type: | Article |
---|---|
ISSN: | 2666-5204 |
Uncontrolled Keywords: | Early warning systems ; Maternal health ; Patient escalation ; Patient safety |
Group: | Faculty of Health & Social Sciences |
ID Code: | 35759 |
Deposited By: | Symplectic RT2 |
Deposited On: | 12 Jul 2021 12:12 |
Last Modified: | 14 Mar 2022 14:28 |
Downloads
Downloads per month over past year
Repository Staff Only - |